SOP for Multi Grade Filter operation

1. Purpose

The purpose of this to lay down the procedure for the operation of Multi Grade Filter.

2. Scope

The procedure covers the operation & backwash of Multi Grade Filter to the formulation plant of a Pharmaceutical Company

3. Procedure

  • Ensure that Multi Grade Filter ( MGF) feed pump suction and discharge valve is in open condition
  • Open MGF inlet valve, Air release valve, and rinse outlet valve. when all the air is released close air release valve.
  • From the rinse outlet valve allow water to drain
  • Rinse the water for 5 minutes & check the water quality, if ok open the service outlet valve.
  • The unit will come into operation
  • Check the filter inlet & outlet pressure across the filter; differential pressure shall not be more than 1Kg/cm2

Following steps shall be followed for stopping the Multi Grade Filter:

  • Off MGF feed pump
  • Close MGF inlet & MGF outlet valve
  • Open MGF air release valve to depressurize the unit

Backwash of MGF

  • Ensure that Multi Grade Filter ( MGF) backwash pump suction and discharge valve is in open condition
  • Close the MGF inlet & MGF outlet valve
  • Open backwash inlet & outlet valve
  • Start the Backwash pump and set flow 1.5 times of service flow rate.
  • After a specified duration of 10 minutes or when water in drain sump is clear, close the backwash inlet & outlet valve
  • Stop backwash pump

Backwash of MGF

  • Ensure that Multi Grade Filter ( MGF) feed pump suction and discharge valve is in open condition
  • Open MGF inlet valve, Air release valve, and rinse outlet valve.
  • Start MGF feed pump
  • When all the air is released close air release valve.
  • Rinse the water for 5 minutes & check the water quality, if ok open the service outlet valve.
  • The unit will come into operation